KX-FF46-RP1, KX-HA-FFRP, KX-GA-VV, KX-HA-FGR thermocouple compensation wire

KX-FF46-RP1, KX-HA-FFRP, KX-GA-VV, KX-HA-FGR thermocouple compensation wire has excellent moisture resistance, wear resistance and flame retardant properties; high temperature resistant fluoroplastic insulation and sheath compensation wire or cable adopts continuous extrusion process, and thermocouple compensation wire is more resistant to high temperature, cold and acid. The superiority of alkali oil water, non-flame retarding and anti-aging, the product quality is higher than the national standard GB/T4989-94 (equivalent to IEC584-3). The intrinsically safe explosion-proof temperature measurement system uses a low-capacitance, low-inductance material structure with compensating wires or cables, and has explosion-proof safety performance. High temperature cable is suitable for explosion-proof thermocouple cold short and explosion-proof temperature measuring instruments in an explosive atmosphere, forming intrinsically safe thermal power. Even temperature measurement system.

Second: product implementation standard GB/T4989-94 (equivalent to IEC584-3 standard)
Three:RS485 cable use characteristics 1. Maximum operating temperature of the conductor: heat resistance grade: polyperfluoroethylene propylene (F46) 200 ° C
Soluble PTFE 260 ° C, silicone rubber cable 180 ° C
General grade: PVC 70 ° C and 105 ° C, cross-linked polyethylene 90 ° C
Low-smoke, halogen-free flame retardant polyolefin 70°C, crosslinked type 90°C and 125°C

  1. Low ambient temperature: PVC sheath: fixed laying -40 ° C, non-fixed laying -15 ° C
    Fluoroplastic insulation and sheath: fixed laying -60 ° C, non-fixed laying -20 ° C
  2. Cable allowable bending radius: Non-armored cable is at least 6 times the outer diameter
    Copper tape shield or steel tape armored cable is 12 times the outer diameter of the cable
    Fluoroplastic insulation and sheath are 10 times the outer diameter of the cable
    Four: Basic model and name KX-FF46-RP1 KX-HA-FFRP KX-GA-VV KX-HA-FGR
    1: k type Thermocouple compensation wire
KX-GA-VVPPolyvinyl chloride insulated and sheathed copper wire braided general shield precision thermocouple with K index
KX-GA-VVRPPolyvinyl chloride insulated and sheathed copper wire braided general shield precision grade K thermocouple compensation soft cable
KX-GA-VPVPPolyvinyl chloride insulated and sheathed copper wire braided screen plus total shielded precision grade K thermocouple compensation cable
KX-GA-VPVRPPolyvinyl chloride insulated and sheathed copper wire braided screen plus total shielded precision grade K thermocouple compensation soft cable
KX-GA-YJVPXLPE insulated, PVC sheathed, copper wire braided general shield, precision grade K thermocouple compensation cable
KX-GA-YJVRPXLPE insulated, PVC sheathed, copper wire braided general shield, precision grade K thermocouple compensation soft cable
KX-GA-YJPVPXLPE insulated PVC sheathed copper wire braided screen plus total shielded precision grade K thermocouple compensation cable
KX-GAYJPVRPXLPE insulated PVC sheathed copper wire braided screen plus total shielded precision grade K thermocouple compensation soft cable
KX-HA-FFPFluoroplastic olefin insulated and sheathed copper wire braided general shield precision thermocouple with K index number thermocouple
KX-HA-FFRPFluoroplastic olefin insulated and sheathed copper wire braided general shield precision grade K thermocouple compensation soft cable
KX-HA-FPFPFluoroplastic insulated and sheathed copper wire braided screen plus total shielded precision grade K thermocouple compensation cable
KX-HA-FPFRPFluoroplastic insulated and sheathed copper wire braided screen plus total shielded precision grade K thermocouple compensation soft cable
KX-HA-FVPFluoroplastic olefin insulated, PVC sheathed, copper wire braided general shield, precision grade K thermocouple compensation cable
KX-HA-FVRPFluoroplastic olefin insulated, PVC sheathed, copper wire braided general shield, precision grade K thermocouple compensation soft cable
KX-HA-FPVPFluoroplastic insulated PVC sheathed copper wire braided screen plus total shielded precision grade K thermocouple compensation cable
KX-HA-FPVRPFluoroplastic insulated PVC sheathed copper wire braided screen plus total shielded precision grade K thermocouple compensation soft cable
KX-HA-FGPFluoroplastic olefin insulated silicon rubber sheathed copper wire braided general shield precision grade K thermocouple compensation cable
KX-HA-FGRPFluoroplastic olefin insulated silicon rubber sheathed copper wire braided general shield precision grade K thermocouple compensation soft cable
KX-HA-FPGPFluoroplastic insulated silicon rubber sheathed copper wire braided screen plus total shield precision grade K thermocouple compensation cable
KX-HA-FPGRPFluoroplastic insulated silicon rubber sheathed copper wire braided screen plus total shield precision grade K thermocouple compensation soft cable
Note: The above basic models only list the shielding method of copper wire or tinned wire. For other shielding type models, just change the shielding code, such as P2 and P3.2 Flame retardant type plus ZR before the model, 22 after the armored cable type, ZR192 is imported PFA material, temperature resistant 260 °C 