The thermocouple compensating wire and compensating cable are a pair of insulated wires with the same nominal value of the matching thermoelectromotive force in a certain temperature range (including high temperature cable and normal temperature), and are used to connect the thermoelectric Even with the measuring device to compensate for the error caused by the temperature change at the junction with the thermocouple. This product is suitable for electrical connection between various thermocouples with temperature numbers S, K, E, T, J and N and temperature display instruments to improve measurement accuracy.2: Conditions of use High temperature compensation wire cable for thermocouple:
(1) Working temperature: heat resistant: up to 200 ° C and 260 ° C,silicone rubber cable;
Generally used: up to 70 ° C and 105 ° C.
(2) Minimum ambient temperature: fluoroplastic insulated and sheathed cable: fixed laying -60 ° C, non-fixed laying -20 ° C;
PVC insulated and sheathed cable: fixed laying -40 ° C, non-fixed laying -15 ° C.
(3) Minimum bending radius: PVC insulated and sheathed cable non-armored cable is not less than 6 times the outer diameter of the cable, fluoroplastic insulated and sheathed non-armored cable is not less than 10 times the outer diameter of the cable, armored cable Not less than 12 times the outer diameter of the Heat Trace Cable.
Product variety and model: see Table 1
product name |
model |
Equipped with thermocouple |
Thermocouple indexing number |
Copper-copper-nickel compensating wire (cable) |
SC |
Platinum rhodium 10-platinum thermocouple Platinum rhodium 13-platinum thermocouple |
S |
Iron-copper-nickel compensating wire (cable) Copper-copper-nickel compensating wire (cable) |
KC A KCB |
Nickel-chromium-nickel silicon thermocouple |
K |
Nickel-chromium-nickel silicon extension type wire (cable) |
KX |
Nickel-chromium-nickel silicon thermocouple |
K |
Iron-copper-nickel compensating wire (cable) Nickel-chromium-silicon-silicon extended conductor (cable) |
NC NX |
Nickel-chromium-silicon-silicon thermocouple |
N |
Nickel-chromium-copper-nickel extension wire (cable) |
EX |
Nickel-chromium-copper-nickel thermocouple |
E |
Iron-copper nickel extension type wire (cable) |
JX |
Iron-copper nickel thermocouple |
J |
Copper-copper-nickel extension wire (cable) |
TX |
Copper-constantan galvanic couple |
T |
High temperature compensation wire cable for thermocouple Model
Name
KX-VV
Compensating wire for PVC insulated and sheathed K-division thermocouple
KX-VPV
Shielded compensation wire for PVC insulated and sheathed copper wire braided shielded K-index thermocouple
KX-FF
Compensating wire for fluoroplastic insulation and sheathing K-division thermocouple
KX-FPF
Fluoroplastic insulated and sheathed copper wire braided shielded K-index thermocouple shielded compensation wire
KX-FV-105
Fluoroplastic insulation heat-resistant 105°C PVC sheathed K-index thermocouple compensation wire
KX-FPV-105
Fluoroplastic insulated copper wire braided shield heat-resistant 105°C PVC sheathed K-index thermocouple shield compensation wire
KX-HF4B
PTFE insulated glass wire braided sheathed K-division thermocouple compensation wire
KX-HF4PB
PTFE insulated copper wire braided shielded glass wool braided sheathed K-index thermocouple shield compensation wire
Note: 1 Other models of compensation wires SC, KC, EX, JX, TX, NC, NX, etc., only need to rewrite the first item of the model, such as: EX-VVP;
2 Shield type: P: copper wire shielding, P1: tinned wire shielding;
3 Fluoroplastic insulation and sheath high-temperature compensation wire is continuously extruded by fluoroplastic, which has good electrical properties and acid and alkali resistance;
4 General (G) general and precision (S) and heat-resistant (H) ordinary and precision (S) compensation wires can be specified in the order.
Table 8 Compensation Cable
Model
Name
KX-VV
Polyvinyl chloride insulated twisted PVC sheathed K-division thermocouple compensation cable
KX-VPV
Polyvinyl chloride insulated twisted copper wire braided sub-shield PVC sheathed K-division thermocouple compensation cable
KX-VPVP
Polyvinyl chloride insulated twisted copper wire braided sub-shield total shield PVC sheathed K-division thermocouple compensation cable
KX-VVP
Polyvinyl chloride insulated twisted copper wire braided overall shield PVC sheathed K-scale thermocouple compensation cable
KX-FF
Fluoroplastic insulated twisted fluoroplastic sheathed K-division thermocouple compensation cable
KX-FPF
Fluoroplastic insulated twisted copper wire braided sub-shield fluoroplastic sheathed K-division thermocouple compensating cable
KX-FPFP
Fluoroplastic insulated twisted copper wire braided sub-shield total shield fluoroplastic sheathed K-division thermocouple compensating cable
KX-FFP
Fluoroplastic insulated twisted copper wire braided overall shield fluoroplastic sheathed K-index thermocouple compensation cable
KX-FV-105
Fluoroplastic insulated twisted heat-resistant 105°C PVC sheathed K-division thermocouple compensation cable
KX-FPV-105
Fluoroplastic insulated twisted copper wire braided sub-shield heat-resistant 105°C PVC sheathed K-division thermocouple compensation cable
KX-FPVP-105
Fluoroplastic insulated twisted copper wire braided sub-shield total shield heat-resistant 105 °C PVC sheathed K-division thermocouple compensation cable
KX-FVP-105
Fluoroplastic insulated twisted copper wire braided overall shield heat resistant 105°C PVC sheathed K index thermocouple compensation cable
KX-HF4B
PTFE insulated twisted glass woven sheathed K-division thermocouple compensation cable
KX-HF4PB
PTFE insulated twisted copper wire braided shielded glass wool braided sheathed K-shield thermocouple shielded compensation cable
KX-HF4PBP
PTFE insulated twisted copper wire braided sub-shield total shield glass wool braided sheathed K-shield thermocouple shielded compensation cable
KX-HF4BP
PTFE insulated twisted copper wire braided general shield glass wool braided sheathed K-shield thermocouple shielded compensation cable
Note: 1 Other models of compensation cables SC, KC, EX, JX, TX, NC, NX, etc., only need to rewrite the first item of the model, such as: EX-VPV;
2 Shielding types are: P: copper wire shielding, P1: tin-plated wire shielding, P3: aluminum/polyester composite film, P2: copper-plastic composite film;
3 Fluoroplastic insulation and sheath high-temperature compensation wire is continuously extruded by fluoroplastic, which has good electrical properties and acid and alkali resistance.
4 General (G) general and precision (S) and heat-resistant (G) ordinary and precision (S) compensation cables can be specified in the order.
5 Intrinsically safe compensation cable should be added “IA-” before the original model, such as: IA-KX-VPVP; for flame retardant compensation cable, “ZR-” should be added before the original model,Flat ribbon cable.