Nitrile flexible flat cable is suitable for power plant coal pile of homework, because the working condition is bad for the requirements of the cable is extremely high, the company imported PVC polymer materials with environmental protection, wear resistance, tensile, prevent oil, flame retardant, UV resistance, waterproof performance, such as car, transmission machinery, elevator, crane, cranes, telescopic mechanical equipment such as portable electric power transmission and control letter way, lighting, communication,pt100 thermocouple also can be used in the indoor environment of a closed moving mechanical parts, such as the connection of the installation.
• product features
1) flat cable has the characteristics of cold resistance,AnHui TianKang (Group)Shares Co.,Ltd softness, abrasion resistance and oil resistance.
2) smaller than the bending radius of the round cable, saving installation space.
3) multiple cables can be overlapped and bundled.
4) high flexibility — multi-strand fine twisted non-oxygen fine copper wire twisted bundle wire conductor, ensuring the softness and flexibility of the wire core.
6) bending resistance — optimized cable pitch, special structural design, high quality raw materials, to ensure that the core is not easily broken in high-frequency bending work for a long time sheathed thermocouple.
7) tensile strength — two reinforced galvanized steel wire ropes.
7) wear resistance, oil resistance and aging resistance — using high-quality mixed sheath materials.
8) water resistance, acid and alkali resistance, radiation protection and corrosion resistance — special protective materials for TPU, seawater and other harsh environment
•Nitrile flexible flat cable structure
Conductor: multi – strand ultrafine stranded non – oxygen copper wire, according to VDE0295CLASS 5 standard
Insulation: special mixed PVC insulation Armored thermal resistance
Color: color indication, in accordance with GB5023.6(yellow, white, orange, light green, pink) number number (no yellow and green earth wire)
Lining: none.
Reinforcing parts: high strength galvanized aviation steel wire (optional);
Jacket: special jacket for cold resistant PVC is grey or black
Rated voltage: 300/500v
Test voltage: 2500V Boiler Thermocouple
Static bending test: 0.3m < 0.6m:
Vertical combustion test: GB/ t18380.1-2001, iec 60332-1:1993
Product standards: GB5023.6, lEC60227 — 6, EN5021 4.
Usage guidelines:
In normal use, the highest conductor temperature is 70 uc
The usage is as follows
When a font is arranged
1. The length of free use is greater than 35m;
2. The operating speed is greater than 1.6m/s;
Should be considered in the cable to add load bearing components, load bearing components are generally galvanized steel wire rope or fiber rope such as aramund yarn
When plum-blossom pattern is twisted and arranged
1. The free suspension length is greater than 80m;
2. The operating speed is 4.0m/s~ 10.0m /s;
Should consider in the cable to add load bearing components, load bearing components are generally galvanized steel wire rope.