I. TVVBG flat cable Overview:
TVVBG flat cable, TVVBG, with steel wire elevator cable, TVVBG400.75 elevator flat cable is suitable for installation in elevator equipment, as equipment connection line, can also be used for elevators and other lifting and similar lifting systems.
TVVBG flat cable is suitable for 300/500V or 450/750V elevators and lifting machinery for power supply connection.http://www.tiankangcable.com/flat-ribbon-cable.html
The TVVBG flat cable is designed, produced and tested in strict accordance with the standard GB/T 5023.6-1997 and the supplementary part appendix 5. The product has excellent performance and durability during use. We use multiple strands of fine strands and fine strands of fine oxygen-free copper wire as conductors, select raw materials according to different needs and use occasions of customers, and do structural design, mechanical and electrical and electrical performance calculation and simulation experiments. Reasonable structural design, strict material selection, excellent production and processing, strict quality control procedures, and marine wire good results in practical applications.
Second, TVVBG flat cable product features:
TVVBG flat elevator cable is a versatile product with market demand. This product has passed the quality, long service life and affordable price, and has been trusted by customers.http://www.tiankangcable.com/marine-cable.html
The conductor is made of multiple strands of fine-twisted oxygen-free copper wire, which is flexible.
Modified flexible environmentally friendly PVC material insulation, oil and water resistance, corrosion resistance, high and low temperature resistance, high mechanical strength, excellent chemical stability and dielectric properties, good product performance and safe use.
TVVBG flat cable for environment -10 ° C ~ 70 ° C
TVVBG flat cable can produce nitrile-polyvinyl chloride insulation and sheathed flat flexible cable according to customer requirements. Reduced size means more space than round cable.
In the case of the same core wire, it has a smaller bending radius than a round cable, making it possible to tie multiple flat cables together.
The horizontal discharge of the core wire does not cause the cables to be twisted together, reducing the probability of occurrence of danger http://www.tiankangcable.com/Heat-Trace-Cable.html.
Third,TVVBG flat cable the use of features:
1. The normal temperature of the conductor is 70 °C during normal use. The product is usually not suitable for use below 0 °C. When the temperature is lower than 0 °C, it can be negotiated between the buyer and the manufacturer, and designed and manufactured according to customer requirements and conditions of use Waterproof rubber flexible cable.
2. The TVVB series cable is intended to be used for elevators and lifts whose free suspension length does not exceed 80m and the moving speed does not exceed about 4m/s. When the cable usage exceeds the above limit, it can be negotiated between the buyer and the manufacturer to increase Bearing components (such as wire rope). The elevator cable that adds the load-bearing member is intended to be installed in elevators and elevators with free suspension lengths greater than 80 m and moving speeds not exceeding 10 m/s.
3, cable insulated core insulated wire core digital number, placed in parallel, cable structure is soft, easy to lay and install, similar size can be designed and improved according to customer needs.
4. The rated voltage of the elevator cable is 1mm and below 300m500V of the nominal section of the core wire, and 450/750V of the core section of 1mm or more http://www.tiankangcable.com/Rubber-cable.html.
The long-term allowable operating temperature of the cable conductor does not exceed 70 ° C, and the ambient temperature of the installation should not be lower than -5 ° C.
Installation free suspension length not exceeding 80 m, moving speed not exceeding 1.6 m/s
Cable laying installations allow the bend radius to be no less than six times the small side of the cable.
0.5 mm2 U0/U 2500V Heat Trace Cable
>1.0 mm2 U0/U 3000V
Small breakdown voltage: 6000V
Temperature range: Mobile installation: -20 ° C ~ +90 ° C
Fixed installation: -30 ° C ~ +70 ° C pur cable
Radiation resistance: 80Mrad{80×106cJ/Kg}
Combustion test: in accordance with VDE 0472 804 Part B Test and IEC 332-1
Fourth, product model and specifications:
T-ladder V-polyvinyl chloride insulation V-polyvinyl chloride sheath B-flat cable P-shield
G-wire reinforcement TV-video transmission line http://www.tiankangcable.com/Polyurethane-cable.html
Curved moving round cable for TVV elevator
TVVB elevator bending resistant moving flat cable (inline) (plum arrangement)
TVVBG elevator flat bending resistant moving cable with steel wire (plum arrangement with steel wire)
TVVBP elevator bending resistant mobile flat cable belt shield
TVVBPG elevator bending resistant moving flat cable with steel wire (with shielding with shield, steel wire)
TVVB(G) elevator accompanying flat cable (lined with wire)
http://www.tiankangcable.com http://www.tksiliconerubbercable.com http://www.chinathermocouple.com