Red silicone rubber flexible cable YGC YGCR YGCRP is suitable for power transmission lines with fixed voltage of 0.6/1KV and below, or connecting cables for mobile electrical appliances. silicone rubber flexible cable have the characteristics of heat radiation, cold resistance, acid and alkali resistance, corrosive gas and waterproof. silicone rubber cable structure is soft and the radiation is convenient. In the high temperature (cold) environment, the electrical performance is stable, the anti-aging performance is outstanding, and the service life is long. Silicone Rubber Electric Cable is widely used in metallurgy, electric power, petrochemical, electronics, automobile manufacturing and other industries.Second: Red silicone rubber flexible cable YGC YGCR YGCRP implementation standards:
Flame retardant and fire resistance test is carried out according to GB12666-90 Rubber cable
Three: Red silicone rubber flexible cable YGC YGCR YGCRP use characteristics:
1. AC rated voltage: U0/U 0.6/1KV
Maximum operating temperature PUR polyurethane cable: 180 ° C
Minimum ambient temperature: fixed laying -60 ° C
2. The high temperature flexible silicone cable installation temperature should not be lower than -25 °C.
3. Cable allows bending radius: cable is at least 10 times the outer diameter of the cable
Four: basic model and name:
Table 1
Red silicone rubber flexible cable YGC YGCR YGCRP model
product k type thermocouple name
YGC
Silicone rubber insulated silicon rubber sheathed power cable
YGC
Silicone rubber insulated silicon rubber sheathed mobile power flexible cable
YGCP
Silicone rubber insulated silicon rubber sheathed copper braided shielded power cable
YGC22
Silicone rubber insulated silicon rubber sheathed steel tape armored power cable
JGG
Silicone rubber insulated silicone rubber sheathing installation line
JGGR
Silicone rubber insulated silicone rubber sheath mobile mounting cable
JGGP
Silicone rubber insulated silicon rubber sheathed copper braided shield mounting wire
JHXG
Silicone rubber insulated motor lead wire
Remark: ZR is added to the flame retardant silicone rubber cable model, and the Marine cable copper wire in the conductor core can be tinned.
Five: code name and meaning
Table 2
Code
Code meaning
Y
Serial code (mobile flexible cable)
G
Silicone Rubber
C
Heavy
twenty two
Steel belt armor
P
Copper braided shield
R
Stranded conductor
J
Motor lead
Six: Red silicone rubber flexible cable YGC YGCR YGCRP main technical indicators
1. The finished Flat ribbon cable conductor (R class) DC resistance (in accordance with the provisions of GB3956) refer to Table 1 and Table 2 of Appendix A.
2.20 ° C insulation resistance is not less than 100MΩ / KM
3. The finished Flexible silicone wire is subjected to AC 50HZ3.5KV/5min voltage test without breakdown.