KFGPR (YGC-KF46RP) shielded control flexible cable

KFGPR (YGC-KF46RP) shielded control flexible cable is suitable for the transmission line of electrical instrument rated voltage 450/750V and below, and the transmission line of automatic control system. silicone rubber cable has excellent performances such as oil resistance, water resistance, wear resistance, acid and alkali resistance, various corrosive gases, aging resistance and non-combustion. Suitable for metallurgy, electric power, petrochemical and other industries.

Two: KFGPR (YGC-KF46RP) shielded control flexible cable implementation standards
Q/HHTZH004.1
Flame retardant and fire resistance test is carried out according to GB12666-90 standard
Three: KFGPR (YGC-KF46RP) shielded control flexible cable use characteristics
1. AC rated voltage: U0/U 450/750KV
2. Maximum working temperature: Polytetrafluoroethylene propylene (F46) insulation does not exceed 200 ° CPUR polyurethane cable
Soluble polytetrafluoroethylene (PFA) insulation does not exceed 260 ° C
3. Minimum ambient temperature: PVC sheath: fixed laying -40 ° C, non-fixed laying -15 ° C
Fluoroplastic and silicone rubber sheath: fixed laying -60 ° C, non-fixed laying -20 ° C
4. The cable installation temperature should not be lower than 0 °C (fluoroplastic, silicone rubber and Dingyue sheathed cable is not lower than -25 °C).
5. Cable allowable bending radius: non-armored cable is at least 6 times the outer diameter of the cable
Copper tape shielded or steel tape armored cable is 12 times the outer diameter of the cable
Fluoroplastic insulated and sheathed cable is at least 8 times the outer diameter of the cable

Four: other flame retardant high temperature cable (control type) model and name

(ZR192-)KFF Fluorine 46 (Imported PFA) Insulated and Sheathed Control Cable
(ZR192-)KFFP Fluorine 46 (Imported PFA) Insulated and Sheathed Copper Wire Braided Shielded Control Cable
(ZR192-)KFFR Fluorine 46 (Import PFA) Insulation and Sheath Control Flexible Cable
(ZR192-)KFF22 Fluorine 46 (Imported PFA) Insulated and Sheathed Steel Tape Armored Control Cable
(ZR192-)KFFRP Fluorine 46 (Imported PFA) insulated and sheathed copper wire braided shielded control flexible cable
(ZR192-)KFFP1 Fluorine 46 (Imported PFA) Insulated and Sheathed Tinned Copper Braided Shield Controlled Flexible Cable
(ZR192-)KFFP2 Fluorine 46 (Imported PFA) Insulated and Sheathed Copper Tape Wrapped Shielded Control Cable Flat ribbon cable
(ZR192-)KFFRP2 Fluorine 46 (Imported PFA) Insulated and sheathed copper tape wrapped shielded control flexible cable
(ZR192-)KFV Fluorine 46 (Imported PFA) Insulated PVC Sheathed Control Cable
(ZR192-)KFVR Fluorine 46 (Imported PFA) Insulated PVC sheathed control flexible cable
(ZR192-)KFVP Fluorine 46 (Imported PFA) insulated copper wire braided screened PVC sheathed control cable k type thermocouple
(ZR192-)KFVRP Fluorine 46 (Imported PFA) insulated copper wire braided screened PVC sheathed control flexible cable
(ZR192-)KFVP2 Fluorine 46 (Imported PFA) Insulated Copper Tape Wrap Shielded PVC Sheathed Control Cable
(ZR192-)KFV22 Fluorine 46 (Imported PFA) Insulated Polyvinyl Chloride Outer Sheath Steel Tape Armored Control Cable
(ZR192-)KFRV22 fluorine 46 (imported PFA) insulated PVC outer sheathed steel tape armored control flexible cable
(ZR192-)KFVP2-22 Fluorine 46 (Imported PFA) insulated copper tape wrapped shielded steel tape armored PVC sheathed control cable
(ZR192-)KFGR(YGC-KF46R) Fluorine 46 (Imported PFA) Insulated Silicone Rubber Sheath Control Flexible Cable
(ZR192-)KFGPR(YGC-KF46RP) Fluorine 46 (Imported PFA) Insulated Silicone Rubber Sheathed Copper Wire Braided Shield Controlled Flexible Cable
Remarks: ZR192 is added before the imported PFA material model. ZR is required before the flame retardant sheath type, and the copper wire in the conductor core can be tinned.
Five: code name and meaning
Table 2

Item Code Description
Flame retardant properties ZR grade A, B, C flame retardant
Series code K control cable
Insulation material F Polyfluoroethylene propylene (F46) maximum operating temperature 200 ° C
Soluble polytetrafluoroethylene (PFA) up to 260 ° C (with model number plus ZR192)
Sheath material F Polyfluoroethylene propylene (F46) maximum working temperature 200 ° C
Soluble polytetrafluoroethylene (PFA) up to 260 ° C (with model number plus ZR192)
V polyvinyl chloride
G silicone rubber
Shielding material P copper wire braided shield
P1 tinned copper wire shield
P2 copper tape wrapped shield
P3 aluminum plastic wrapping shield
Armored material 22 steel tape armored PVC sheath
23 steel tape armored polyethylene sheath
32 steel wire armored PVC sheath
33 steel wire armored polyethylene sheath
Conductor structure A single conductor
B 7 stranded conductor
R stranded conductor
Six: main technical indicators
1. Finished cable conductor DC resistance (in accordance with GB3956 regulations) refer to Table A of Appendix A
2.20 ° C insulation resistance is not less than 500MΩ / KM
3. The finished cable is subjected to AC 50HZ3.0KV/5min voltage test without breakdown.

Leave a comment