Silicone Rubber Cable HTKGG HTKGGP HTKGGX HTKGGPX HTKFG

Silicone Rubber Cable HTKGG HTKGGP HTKGGX HTKGGPX HTKFG Applicable to AC and DC 50Hz rated voltage 450/750V and below electrical instrumentation and automation control system signal transmission line and various mobile electrical connection lines.

Silicone Rubber Cable HTKGG HTKGGP HTKGGX HTKGGPX HTKFG Use characteristics
(1) Working temperature: long-term working high temperature cable does not exceed 180 ° C
(2) Rated voltage U0/U: 450/750V
(3) Minimum ambient temperature: fixed laying -60 ° C
                  Non-fixed laying -20 ° C
(4) Minimum bending radius: the bending radius is not less than 4 times the outer diameter of the cable
Silicone Rubber Cable HTKGG HTKGGP HTKGGX HTKGGPX HTKFG  Model and name
model
name
HTKGG
Copper core silicone rubber insulated and sheathed control cable
HTKGGP
Copper core silicone rubber insulated and sheathed copper wire braided shielded control cable
HTKGGx
Tinned copper core silicone rubber insulated and sheathed control cable
HTKGGPx
Tinned copper core silicone rubber insulated and sheathed copper wire braided shielded control cable
HTKFG
Copper core fluoroplastic insulated silicon rubber sheathed control cable
Nominal cross section mm2
Silicone Rubber Cable HTKGG HTKGGP HTKGGX HTKGGPX HTKFG Technical indicators
 
0.5mm2
 
0.75mm2
1.0mm2
1.5mm2
2.5mm2
20 ° C Ω / KM
classification
Not tinned
Tin plating
Not tinned
Tin plating
Not tinned
Tin plating
Not tinned
Tin plating
Not tinned
Tin plating
B
36.0
5.09
36.0
5.09
36.0
5.09
36.0
36.0
5.09
5.09
R
39.0
3.39
39.0
3.39
39.0
3.39
39.0
39.0
3.39
3.39
Test voltage (v/5min)
3500
Insulation resistance (MW/KM)
20 ° C is greater than 50
Z
Meet the GB12666.5-90 oxygen index is greater than 50 higher than Class B k type thermocouple requirements
project
unit
Description
Serial code
 RS485 cable
HTK
Special control cable
Insulation Materials
G
Silicone Rubber
F
Fluoroplastics (FEP)
Shielding material
P
Copper wire weaving
P1
Tinned copper wire weaving
P2
Aluminum plastic belt
Jacket material
G
Silicone Rubber
Conductor material
/
Copper wire omitted
X
Tinned copper wire
Conductor structure
B
Seven stranded conductor
R
Multi-strand soft conductor
specification

Number of cores × conductor surface (N × S)

N: 2,3,4,5…….37
Conductor cross-sectional area

S: 0.5, 0.75, 1.0, 1.5, 2.5 (mm2)
Example: 1.19 core carrier surface is 1.0mm2B conductor tinned wire core silicone rubber insulation and sheath special control cable is expressed as: HTKGGBx 19×1.0mm2.

2.19 core carrier surface is 1.0mm2R type conductor silicon silicone rubber edge and sheath tinned copper wire braided shield special control cable is expressed as: HTKGGP1Rx 19×1.0mm2.

3.19 core carrier surface is 1.0mm2, tinned wire core silicone rubber insulation and sheath special control cable is expressed as: HTKGGx 19×1.0mm2.

4.19 core carrier surface is 1.0mm2B type conductor tinned wire core fluoroplastic insulated silicon rubber sheathed aluminum plastic belt shielding special control cable expressed as: HTKFGP3Bx 19×1.0mm2.

Leave a comment